When you need to set or change these values, you must go through the
Adjust/Store procedure as follows.
1. Press Local Control. The button will light up indicating you now have local control of
the 1788Aʼs front panel.
2. Set the Mode to MIDI.
3. Toggle the Set I.D. button to Channel, Device or Net - whichever is due to be updated.
4. Press Adjust/Store. It will light up.
5. Spin the ADJUST dial to set the correct number in the General Status Readout. Select
other I.D.s as desired and adjust their values.
6. When the desired numbers are updated, press Adjust/Store again to store the update.
The Adjust/Store button will go off indicating the values were stored and youʼre back in
safe mode.
7. Put the 1788A into the correct remote interface port by using the Mode button.
For the 188 follow these instructions:
Turn the encoder clockwise until you get to a screen that shows SYSTEM CONFIGURE.
In order to safeguard against unwanted changes to the system configuration, the rotary
encoder must be pressed in for several seconds. The system configuration includes
clock source, format and sample rate, display contrast, Net Number assign, DHCP/IP
select and system configure exit.
DHCP/FIXED IP
DHCP requires a network router, which will ʻserveʼ an IP address dynamically. Fixed IP
forces the address that is programmed into the unit and modified by the Net Number.
The letter ʻDʼ will be in front of the IP address when DHCP is selected and the letter ʻFʼ
will be in front of the IP address when Fixed IP is selected. For our needs, this MUST be
set to DHCP.
CONNECTIONS
Connect a CAT5 patch cable from the 188 and the 5200 to the 100 Base-T network
router via CAT5.
The following Aphex channel parameters cannot be adjusted from AVID Pro Tools:
1. Mute on/off (1788A feature)
1788A and 188 Remote Control in Pro Tools
The following parameters can be remotely controlled in Pro Tools:
Input Gain
48V on/off
MicLim on/off (1788A only)
Pad on/off
Phase Invert on/off
High-Pass Filter on/off